M16

  • Светодиод, лампа накаливания и неоновая лампа
  • Защелкивающийся контактный блок
  • Малая установочная глубина (менее 28,5 мм ниже уровня панели)
  • Высокая надежность, степень защиты IP65
  • Сертификаты UL, CSA и VDE, соответствие EN60947-5-1
Omron M16

Характеристики и информация для заказа

Pushbutton

Type Display color Order code
IP65 oil-resistant
Rectangular Square Round
LED
Incandescent lamp
Red A165L-JR A165L-AR A165L-TR
Yellow A165L-JY A165L-AY A165L-TY
Pure yellow A165L-JPY A165L-APY A165L-TPY
White A165L-JW A165L-AW A165L-TW
Blue A165L-JA A165L-AA A165L-TA
LED
Incandescent lamp
Green A165L-JGY A165L-AGY A165L-TGY
Green A165L-JG A165L-AG A165L-TG

Lamp

Type Color Order code
Operating voltage
5 VDC 12 VDC 24 VDC
LED Red A16-5DSR A16-12DSR A16-24DSR
Yellow A16-5DSY A16-12DSY A16-24DSY
Green A16-5DSG A16-12DSG A16-24DSG
White A16-5DSW A16-12DSW A16-24DSW
Blue A16-5DA A16-12DA A16-24DA
Type 5 VAC/VDC 12 VAC/VDC 24 VAC/VDC
Incandescent lamp A16-5 A16-12 A16-24

Case

Classification Order code
IP65 oil-resistant Rectangular A165-CJM
Square A165-CAM
Round A165-CTM

Socket

Classification Order code
Solder terminals M16-0
PCB terminals M16-0P
Screw-less clamp M16-S
Solder terminals Voltage-reduction lighting 100 V M16-T1
Screw-less clamp 100 V M16-T1-S
200 V M16-T2-S

Specifications

Allowable operating frequency Mechanical Momentary operation: 120 operations/minute max., alternate operation: 60 operations/minute max.
Electrical 20 operations/minute max.
Durability Mechanical Momentary operation: 2,000,000 operations min.,
alternate operation: 200,000 operations min.
Electrical 100,000 operations min.
Degree of contamination 3 (IEC947-5-1)
Ambient temperature Operating: -10 to 55°C
(with no icing or condensation)
Storage: -25 to 65°C
(with no icing or condensation)
Weight Approx. 10 g (in the case of a lighted DPDT switch with solder terminals)
Size in mm Round/square: 18Hx18Wx28.5D
rectangular: 18Hx24Wx28.5D
Agency Standards File number
UL, cUL UL508 E41515

Ratings

Superbright LED
Rated voltage Rated current Operating voltage Built-in limiting resistance
5 VDC 30 mA (15 mA) 5 VDC ±5% 33 Ω (68 Ω)
12 VDC 15 mA 12 VDC ±5% 270 Ω (560 Ω)
24 VDC 10 mA 24 VDC ±5% 1,600 Ω (2,000 Ω)
Incandescent lamp
Rated voltage Rated current Operating voltage
6 VAC/VDC 60 mA 5 VAC/VDC
14 VAC/VDC 40 mA 12 VAC/VDC
28 VAC/VDC 24 mA 12 VAC/VDC